An RCD (Residual Current Device) is a safety switch in your consumer unit designed to cut power the instant it detects a leak of current — the kind that could cause an electric shock or start a fire. So when it trips, it's not malfunctioning — it's doing exactly what it's built to do. The question is what's triggering it.
Quick Answer: Most Common Causes
- A faulty appliance plugged into a socket on that circuit
- Damp or water ingress in wiring, sockets, or outdoor fittings
- A damaged cable somewhere on the circuit
- Several appliances on one RCD, each leaking a little current, adding up to enough to trip it
- A fault in the RCD itself, particularly in older consumer units
RCD Keeps Tripping vs. MCB Keeps Tripping — What's the Difference?
An RCD and an MCB (Miniature Circuit Breaker) protect against different things, and knowing which one is tripping narrows down the cause fast:
- RCD trips → usually points to a current leak (damp, damaged insulation, a faulty appliance)
- MCB trips → usually points to overload (too many appliances) or a short circuit
- RCBO trips → could be either. An RCBO combines an RCD and an MCB in one device protecting a single circuit, so it trips on a current leak, an overload or a short circuit
If you're not sure which one is tripping, check your consumer unit — RCDs are typically labelled with a "T" (test) button, MCBs are the individual circuit switches.
What Causes an RCD to Trip But Not the MCB
This is a common and specific symptom — it usually means the fault is a genuine current leak (RCD's job) rather than an overload or short (MCB's job). Common causes include:
- A faulty or damp outdoor fitting (garden lighting, an outdoor socket)
- A washing machine, dishwasher, or other appliance with a developing internal fault
- Condensation or damp inside an older consumer unit itself
What You Can Safely Check Yourself
- Unplug everything on the affected circuit, then reset the RCD — if it holds, plug items back in one at a time to find which one is causing it. Stop using that appliance until it has been repaired or replaced
- Look for anything obviously damp, such as outdoor sockets after rain or a leak near wiring. Look only: do not touch wet fittings or open anything up
- Don't keep resetting it repeatedly if it trips again immediately — that's a sign to stop and call someone
When to Call an Electrician
- The RCD trips again immediately after resetting, with nothing plugged in
- You can't identify which appliance or circuit is causing it
- It's happening repeatedly over several days
- There's a burning smell, discolouration, or visible damage at the consumer unit
This is exactly what our electrical fault finding service is built for — fixed at £78.00 inc. VAT, with calibrated testing equipment used to isolate the actual cause rather than guesswork. For more on how professional fault diagnosis works more broadly, see our electrical fault finding guide.
Is a Tripping RCD an Emergency?
Not usually — a single trip that resets cleanly is the system working as intended. But if it's tripping repeatedly, won't reset at all, or is accompanied by a burning smell or exposed wiring, treat it as urgent. Our emergency response service covers this, from £156–£210 inc. VAT with a 60–90 minute response time.
FAQs
Why does my RCD keep tripping for no reason?
It's rarely "no reason" — it's usually an intermittent fault that's hard to spot, like a damp outdoor fitting or a developing appliance fault. A professional fault-finding visit can isolate it properly.
Is it dangerous to keep resetting a tripping RCD?
Resetting it once to test is fine. Repeatedly resetting an RCD that keeps tripping immediately is not advised — it means there's an active fault, and repeated resets don't fix the underlying cause.
Can I fix an RCD fault myself?
Identifying which appliance is causing it is safe to do yourself by unplugging and testing one at a time. Fixing wiring or consumer unit faults should always be done by a registered electrician.
How fast should a 30mA RCD trip?
A standard 30mA RCD should trip within 300 milliseconds when tested at its rated 30mA, and within 40 milliseconds at five times that current (150mA). These times are measured by an electrician with an RCD tester. The test button on the device only confirms that the trip mechanism works.